- Coronary Stents Coronary Balloons Catheters Guide Wires Introducer Sheaths Accessories Peripheral Interventional Products
- Immunoassay Molecular Diagnostics Hematology Diagnostics POCT Lab Solution
- Structural Heart Diseases Products
- Vascular Access Blood Pressure Transducer Arterial Blood Sampler CVC Accessories IV Catheter Needle-free Connectors Insulin Injection Pain Relief
- Hemodialysis consumables Hemoperfutor Dialysis machine
- ECG Patient Monitor Oximeter
- Cardiovasculars Oncology Anti-infectives Central Nervous System Others
- Surgical Staplers Endoscopy Endoscopic Ultrasound System
- Trauma Implant Spinal Implant Artificial Joint Sports Medicine
- Pacemakers and Leads Equipments
- ELISA CLIA FIA
- Nucleic Acid Extraction Nucleic Acid Extraction & PCR Kits Real-Time PCR
- Thrombelastography Analyzer Blood Grouping Platelet Aggregation
- POCT - FIA Colloidal Gold Blood Glucose Cholesterol SARS-CoV-2
- NeoECG Holter Monitor Portable ECG Monitor AI-ECG Pocket ECG
- Patient Monitor Vital Signs Monitor End-tidal Capnography
- Fingertip Oximeter Handheld Oximeter Wrist Oximeter Wearable Oximeter All-in-One Health Monitor POCT Solution
- OBS Locking Compression Plate Locking Plates Conventional Plates Mini Plates System Screws Patella Ring - Patented Product Metal Pins Cable System
- Fusion Cage Cervical Fixation System Internal Fixation System Laminoplasty Plate System Percutaneous Kyphoplasty
- Hip System Knee System
- Suture Anchor Suture Button
Diagram and Technical Parameters:

Specifications & models:
| Specification &model | Outer diameter of distal | Outer diameter of proximal | Effective length | Inner diameter of lumen |
| LPMC1826150 | 1.8F | 2.6F | 150cm | 0.016″ |
| LPMC1826130 | 1.8F | 2.6F | 130cm | 0.016″ |
| LPMC1923150 | 1.9F | 2.3F | 150cm | 0.016″ |
| LPMC1923130 | 1.9F | 2.3F | 130cm | 0.016″ |
Common specifications,it is recommended to stockpile.
Features:

Application Scenarios:

Precautions:
Before removing the micro-catheter from the coil, the coil needs to be flushed with heparin saline through the end of the coil to moisten the hydrophilic coating on the surface of the micro-catheter, in order to avoid abrasion of the catheter surface during the withdrawal process
Before the micro-catheter is delivered into the body, a syringe should be used to inject heparin saline into the lumen through the catheter hub to evacuate the air in the lumen and to avoid thrombosis in the lumen
The guide wire and micro-catheter should be inserted as a whole through RHV and into the guiding catheter
The micro-catheter should be rotated moderately and advanced slowly during the operation. When resistance is encountered and it is impossible to advance, try to rotate the micro-catheter appropriately, do not push violently and over-rotate